| FasTesT™ loss/length specifications(a) | |
| Testing speed(d) | FasTesT™ Duplex: 2.6 seconds (two wavelengths, one direction, automated, IL + fiber length) FasTesT™ Simplex: 5 seconds (two wavelengths, bidirectional, automated, IL + ORL + fiber length) |
| Input/Output connectors | Interchangeable adapter (LC, SC or FC)(c) |
| Wavelengths (nm)(d) | 850 ± 20; 1300 ± 20; 1310 ± 20; 1550 ± 20 |
| Source type | LED (multimode) Laser (singlemode) |
| Launch condition(e) | EF compliancy guaranteed at multimode source port Within TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 Encircled Flux template limits at the end of an EXFO reference-grade 50/125 µm test cord |
| Loss range (dB)(f) | Multimode: 20 Singlemode Simplex: 45 Singlemode Duplex: 50 |
| Length measurement range (km) | Multimode: 20(g) Singlemode: 160 |
| Length measurement uncertainty(d,h) | ±(0.5 m + 0.5 % x length) |
| ORL measurement range (dB)(d,i) | 50 |
| ORL measurement uncertainty (dB)(d,i,j) | ±1 |
| Source | |
| Output power (dBm)(d) | Multimode: −25 Singlemode: 2.5 |
| Output power stability (dB) | ±0.05 over 8 h |
| Spectral width (FWHM) (nm) | 850 nm: 30 to 60 1300 nm: 100 to 150 |
| FasTesT mode | Simplex and Duplex |
| Power meter specifications(a) | |
| Detector type | GeX |
| Uncertainty(b) | ±(5 % + 10 nW) |
| Measurement range (dBm) | 25 to −50(c) |
| Wavelengths range (nm) | 850, 1300, 1310, 1490, 1550, 1577, 1625, 1650 |
| Tone detection (Hz) | 270/330/1000/2000 |
| Visual fault locator (VFL) (optional) | |
| Laser | 650 nm ± 10 nm |
| Mode | CW/Modulate 1 Hz |
| Typical Pout in 62.5/125 µm | > −1.5 dBm (0.7 mW) |
| Laser safety | Class 2 |
| a. All specifications valid at 23 °C ± 1 °C and 1550 nm, on batteries and after 15 minutes of warm up, unless otherwise specified. b. Uncertainty is valid at calibration conditions. c. Specifications are provided with FC type connectors. d. Typical. e. Measured at 850 nm with SC connector. f. Typical value, at 850 nm for multimode and 1550 nm for singlemode. g. At 1300 nm. h. In duplex. i. ORL measurement available on MaxTester 945 singlemode wavelengths only. j. No discrete reflectance greater than −65 dB. Up to 45 dB. | |
| Temperature | Operating: −10 °C to 50 °C (14 °F to 122 °F) |
| Relative humidity | 0 % to 95 % non-condensing |
| Display | 7-in (178-mm) outdoor-enhanced touchscreen, 800 x 480 TFT |
| Size (H x W x D) | 166 mm x 200 mm x 68 mm (6 9/16 in x 7 7/8 in x 2 ¾ in) |
| Weight (with battery) | 1.5 kg (3.3 lb) |
| Interfaces | Two USB 2.0 ports RJ45 LAN 10/100 Mbit/s |
| Storage | 6 GB internal memory (150 000 test results, typical) |
| Battery(b) | Rechargeable lithium-polymer battery 12 hours of operation |
| Power supply | AC/DC adapter, input 100-240 VAC, 50-60 Hz, 9-16 V DCIN 20 W minimum |
| Warranty (year) | 1 |
| Calibration interval (years) | 3 |
| a. −20 °C to 60 °C (−4 °F to 140 °F) with the battery pack. b. Typical. | |