完整规格

FTBx-945 Telco OLTS

概述
多功能光损测试设备(OLTS),适用于 FTB-2和FTB-2 PRO平台。
FTBx-945 Telco OLTS

主要优点

  • 得益于FasTesT分析功能,可在5秒的时间内,在两个波长上完成100%自动的双向测试
  • 100%自动的光纤检测:只需一步操作,便可完成光纤双端通过/未通过分析
  • 自带帮助和诊断功能,减少基准测试错误和异常损耗
  • 可更好地测量短光纤
  • 兼容FTB-2和FTB-2 PRO平台
  • 其单模测试距离高达200 km,为业内最佳

应用

  • FTTx construction
  • Telecommunications and outside plant network testing
  • Data centers
  • Enterprise structured cabling

规格

Technical specifications
Power meter specifications(a)
Detector type InGaAs
Uncertainty(b) ±(5 % + 32 pW)
Measurement range (dBm) 5 to −75
Calibrated wavelengths (nm) 850, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1383, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650
Tone detection (Hz) 270/330/1000/2000
Source specifications(a)
Output power (dBm)(c) Multimode (850 nm/1300 nm): −25
SM1 (1310 nm/1550 nm): 2.5
SM3 (1310 nm/1550 nm/1625 nm): 1 / −1 / −5
SM4 (1310 nm/1490 nm/1550 nm): 1 / −5 / −1
Output power stability (dB) ±0.05 over 8 h
Spectral width (FWHM) (nm) 850 nm: 30 to 60
1300 nm: 100 to 150
FasTest™ loss/length specifications(a)
Testing speed(c) FasTest™ Simplex: 3 seconds (two wavelengths, bidirectional, automated, IL + fiber length)
FasTest™ Simplex: 6 seconds (three wavelengths, bidirectional, automated, IL + ORL + fiber length)
Wavelengths (nm)(c) Multimode (LED): 850 ± 20; 1300 ± 20
Singlemode (Laser): 1310 ± 20; 1490 ± 10; 1550 ± 20; 1625 ± 10
Launch condition(d) Encircled Flux (EF) compliancy guaranteed at 50/125 µm multimode source port. Within TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 EF template limits at the end of an EXFO reference-grade 50/125 µm test cord.
Loss range (dB)(e) Multimode: 20
Singlemode simplex: 45
Singlemode duplex: 50
Length measurement range (km)f Multimode: 20
Singlemode: 200
Length measurement uncertainty(c) Duplex: ±(0.5 m + 0.5 % × length)
Simplex: ±(1 m + 0.5 % × length)
ORL measurement range (dB)(c) 50
ORL measurement uncertainty (dB)(c, g) ±1
a. All specifications valid at 23 °C ± 1 °C and 1550 nm, on batteries and after 15 minutes of warm up, unless otherwise specified.
b. Uncertainty is valid at calibration conditions.
c. Typical.
d. Measured at 850 nm with SC connector.
e. Typical value, at 850 nm for multimode and 1550 nm for singlemode.
f. At 1300 nm for multimode and 1550 nm for singlemode.
g. No discrete reflectance greater than −65 dB. Up to 45 dB.
General specifications
Size (H × W × D) 158 mm x 25 mm x 196 mm (6 ¼ in x 1 in x 7 ¾ in)
Weight 0.4 kg (0.9 lb)
Temperature Operating: 0 °C to 50 °C (32 °F to 122 °F)
Storage: −30 °C to 70 °C (−22 °F to 158 °F)
Relative humidity 0 % to 95 % non-condensing