| SPECIFICATIONS | ||
| POWER CHECKER | ||
| OX1-I, OX1-M, OX1-PRO-I, OX1-PRO-M, OX1-PRO-MI | OX1-PRO-M-PPM | |
| Wavelengths (nm) | 1310, 1490, 1550, 1577, 1625, 1650 | 1310, 1490, 1550, 1577, 1625, 1650, 1490 + 1550, 1490 + 1577 |
| Power range (dBm) f | –60 to 15 | –60 to 23 |
| Maximum input power (dBm) | 17 | 23 |
| Power uncertainty g | ±0.5 dB at –20 dBm | |
| Tone detection h | 270 Hz, 330 Hz, 1 kHz, 2 kHz | |
| LIGHT SOURCE | ||
| Wavelengths | 1310 nm ± 30 nm; 1550 nm ± 30 nm; 1650 nm ± 10 nm | |
| Output power (dBm) i, j | > –8 | |
| Output power stability | ±0.2 dB after 30-minute warmup ([Max. - Min.]/2) | |
| Source modulation | CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz | |
| LASER SAFETY | ||
| Compliance | Complies with FDA 1040.10 and IEC 60825-1:2014 | |
| FIBER EXPLORER | ||
| Wavelengths | 1310 nm ± 30 nm; 1550 nm ± 30 nm; 1650 nm ± 10 nm (integrated filter isolation: 50 dB from 1265 nm to 1617 nm) | |
| Maximum link loss (dB) | 15 | |
| Testing time | Flash Advisor (Distance, IL, ORL): 3 seconds | |
| Testing time | Fault Explorer (Distance, IL, ORL, fault exploration): down to 5 seconds b | |
| Testing time | Link Mapper (Distance, IL, ORL, mapping of detectable elements): down to 10 seconds b | |
| Distance uncertainty | ±1.5 m c | |
| Calibration interval (years) | 10 | |
| CONNECTIVITY-TO-SPLITTER CHECK d, e | ||
| Splitter type | Up to 1:64 | |
| Maximum link length (km) | 20 | |
| Maximum last-mile fiber length (km) | 5 | |
| Maximum last-mile fiber loss (dB) | 2.5 | |
| Minimum fiber length after splitter e | 1:2 splitter: 25 m | |
| Minimum fiber length after splitter e | 1:4 splitter: 35 m | |
| Minimum fiber length after splitter e | 1:8 splitter: 150 m | |
| Minimum fiber length after splitter e | 1:16 splitter: 250 m | |
| Minimum fiber length after splitter e | 1:32 splitter: 500 m | |
| Minimum fiber length after splitter e | 1:64 splitter: 1000 m | |
| a. All specifications are typical at 23 °C ± 2 °C unless otherwise stated. b. For Fault Explorer and Link Mapper, typical measurement time varies from 5 to 40 seconds depending on link loss and number of faults. c. Distance uncertainty given for a 5 km link with 3 dB total insertion loss and –42 dB reflectance, excluding index-of-refraction uncertainty. d. Connectivity-to-splitter check is available only with Optical Explorer PRO models. e. Minimum fiber length after the splitter assumes the splitter is the one closest to the subscriber. f. Display shows high and low values when measurements are outside the specified range. g. Power uncertainty applies in broadband mode when the Optical Explorer connector quality is rated 5 stars by optical output diagnosis. h. Tone detection specifications require use of an EXFO optical light source. i. Maximum input power requires a power meter/checker with measurement range ≥15 dBm. j. For the PRO-MI option, average output power at 1 % duty cycle is > –10 dBm. | ||
| Display | 4-inch touch screen |
| Size (H × W × D) | 171 mm × 93 mm × 48 mm (6 3/4 in × 3 11/16 in × 1 7/8 in) |
| Weight | 0.5 kg (1.1 lb) |
| Battery autonomy | >10 hours (typical use) |
| Battery charging | < 5-hour charge time when unit is off |
| Charging connector | USB Type-C charging port connector |
| AC/DC charger/adapter | Input: 100 - 240 V; 50/60 Hz; 1.0 A max; output: 5 V; 2 A |
| Interfaces | Wi-Fi 802.11 b/g/n 2.4 GHz, up to WPA2 encryption |
| Interfaces | Bluetooth 4.2 with BLE, Class 2 (compatible with 4.0 smartphones) |
| Storage capacity | 1000 test results |
| Reporting | Single or batch of tests: PDF on the mobile app and FastReporter |
| Temperature (operating) | –10 °C to 45 °C (14 °F to 113 °F) |
| Temperature (storage) | –40 °C to 70 °C (–40 °F to 158 °F) a |
| Relative humidity range | ≤ 93 %, non-condensing |
| Drop resistance | 1 m (39 in) |
| Display mirroring | From VNC client |
| Warranty (year) | 1 |
| a. To maintain optimal battery performance, avoid exposing the unit to high storage temperatures for long periods. | |