Especificaciones completas

MAX-720D - Access OTDR

Resumen
Fully featured, entry-level, dedicated OTDR with tablet-inspired design; perfect for construction, troubleshooting and everyday field testing in any access network.
MAX-720D - Access OTDR

Características principales

  • Rugged, handy, lightweight, tablet-inspired design built for outside plant 
  • 7-inch, outdoor-enhanced touchscreen–the biggest in the handheld industry
  • 12-hour autonomy
  • Dynamic range of up to 36 dB in singlemode and 29 dB in multimode
  • FTTx in-service testing at 1650 nm with optional in-line GPON/XGS-PON power meter
  • Swap-Out connector, replaceable whenever necessary for optimal performance over time without undue service cost and downtime

Aplicaciones

  • Access network construction and troubleshooting
  • FTTx/PON testing though splitters (up to 1x32)
  • FTTx service activation: GPON, EPON, XGS-PON, 10GE EPON
  • Central office link certification
  • Data center and private networks
  • Tier-2 certification of private/enterprise
  • LAN/WAN characterization
  • Fronthaul/backhaul

Especificaciones

Technical specifications
IN-LINE POWER CHECKERb, l, m
Power range (dBm)–60 to 23
Power uncertainty (dB)j, k±0.5
Calibrated wavelengths (nm)1310, 1490, 1550, 1625, 1650
Selectable wavelengths (nm)1310, 1490, 1550, 1577, 1625, 1650
Tone detection270 Hz/330 Hz/1 kHz/2 kHz
TECHNICAL SPECIFICATIONS
Display7-in (178-mm) outdoor-enhanced touchscreen, 800 × 480 TFT
InterfacesTwo USB 2.0 ports
RJ45 LAN 10/100 Mbit/s
Storage2 GB internal memory (20 000 OTDR traces, typical)
BatteriesRechargeable lithium-polymer battery
12 hours of operation as per Telcordia (Bellcore) TR-NWT-001138
Power supplyPower supply AC/DC adapter, input 100-240 VAC, 50-60 Hz
Wavelength (nm)b850 ± 20/1300 ± 20/1310 ± 30/1550 ± 30/1650 ± 15
Live wavelength (nm)1650
Isolation: 50 dB from 1265 nm to 1617 nm
Dynamic range (dB)c26/29/36/35/35
Event dead zone (m)dSM: 0.7
MM: 0.7
Attenuation dead zone (m)SM: 2.5e
MM: 2.5f
PON dead zone (m)g35
Distance range (km)MM: 0.1 to 40
SM: 0.1 to 260
Pulse width (ns)MM: 3 to 1000
SM: 3 to 20 000
MM launch conditionshEF-compliant
Linearity (dB/dB)±0.03
Loss threshold (dB)0.01
Loss resolution (dB)0.001
Sampling resolution (m)MM: 0.04 to 5
SM: 0.04 to 10
Sampling pointsUp to 256 000
Distance uncertainty (m)i±(0.75 + 0.0025 % × distance + sampling resolution)
Measurement timeUser-defined
Reflectance accuracy (dB)b±2
Typical real-time refresh (Hz)4
BUILT-IN POWER METER SPECIFICATIONS (GeX) (optional)e
Calibrated wavelengths (nm)850, 1300, 1310, 1490, 1550, 1577, 1625, 1650
Selectable wavelenghts (nm)850, 1300, 1310, 1490, 1550, 1577, 1625, 1650
Power range (dBm)a27 to –50
Uncertainty (%)f±5 % ± 10 nW
Display resolution (dB)0.01 = max to –40 dBm
0.1 = –40 dBm to –50 dBm
Automatic offset nulling rangea, gMax power to –30 dBm
Tone detection (Hz)270/330/1000/2000
SOURCE
Output power (dBm)dMM: –2
SM: –8
ModulationCW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
TECHNICAL SPECIFICATIONS (in-line PON power meter with OPM2 in option)a, b
Power range (dBm)–60 to 23
PON power meter (nm)Two channels: 1490/1550 and 1490/1577
Power uncertainty (dB)f, h±0.5
Calibrated wavelengths (nm)1310, 1490, 1550, 1625, 1650
Selectable wavelengths (nm)1310, 1490, 1550, 1577, 1625, 1650, 1490/1550, 1490/1577
VISUAL FAULT LOCATOR (VFL) (optional)
Laser650 nm ± 10 nm
CW/Modulate1 Hz
Typical Pout in 62.5/125 µm> –1.5 dBm (0.7 mW)
Laser safetyClass 2
a. All specifications valid at 23 °C ± 2 °C with an FC/APC connector, unless otherwise specified. b. Typical. c. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1. d. Typical, for reflectance of –55 dB in SM and –45 dB in MM. e. Typical, for reflectance at –55 dB, using a 3-ns pulse. f. Typical, for reflectance at –45 dB, using a 3-ns pulse. g. Non-reflective FUT, non-reflective splitter, 13-dB loss, 50-ns pulse in SM, typical value. h. Compliant with Encircled Flux TIA-526-14-B and IEC 61280-4-1 Ed. 2.0 using an external EF conditioner (SPSB-EF-C-30). i. Does not include uncertainty due to fiber index. j. At calibrated wavelengths. k. Requires a good entry connector’s health. l. Not available when OPM2 is selected. m.Specifications valid when OTDR not in operation or in idle mode.
General specifications
Size (H × W × D)166 mm × 200 mm × 68 mm (6 9/16 in × 7 7/8 in × 2 3/4 in)
Weight (with battery)1.5 kg (3.3 lb)
TemperatureOperating
Storage
–10 °C to 50 °C (14 °F to 122 °F)
–40 °C to 70 °C (–40 °F to 158 °F)c
Relative humidity0 % to 95 % non-condensing
Warranty (year)1
c. –20 °C to 60 °C (–4 °F to 140 °F) with the battery pack.